Search for Permits

Use the search below to get details on plan review activities and review comments on your plans. This information is updated Monday through Friday at 12:30 p.m. and 5:30 p.m.

Information returned on this page is valid through 6/27/2022. Incorporating the new permitting system data into this website is in progress. For current data requests, please contact PermitTechSupport@arlingtonva.us

 
Permit #B2001305
Address4770 LEE HWY
TypeCNEW
StatusFINALED
Permit HolderTRINITY GROUP CONSTRUCTION INC
OwnerALPINE INVESTMENT HOLDINGS LLC
Applied Date06/10/2020
Approved Date01/14/2021
Date Issued01/14/2021
DescriptionNEW 3 STORY BUILDING FOR USE AS A DAY CARE CENTER OVER A 1 LEVEL BELOW GRADE PARKING STRUCTURE SPECIAL INSPECTION REQUIRED

  View Event Log.      View Status.       View Required Plan Review       View Printer Version.   
  
  
Search Again

 
ReviewBuilding
Review Date09/03/2020
StatusApproved
Comments
Sheet A-015 Egress Plans: Where did design factor of 75 come from for outdoor play area? Refer to Table 1004.1.2 - 50 gross for exercise should be load factor
-------------------------------------------------------------------------------------------------------------------
UPDATED REVIEW COMMENT 9/3/2020: 75 load factor is for daycare requirement. However, building code requirement is more stringent at 50 gross. Must comply with VUSBC 2015 1004.1.2.
  



  
 
Search Permits By:   Address
Permit Number
Date